Kingspan Safepro2 Anchor & Cable System

A high-strength anchor and cable system with energy-absorbing posts that limit the fall arrest load to less than 6kN.

Description

 

Comprised of high-strength steel cable supported on energy-absorbing roof anchor posts, limiting the fall arrest roof load to less than 6kN.
 

    • Fully compliant with AS NZS 1891.2 & 1891.4, BS EN 795: D and OHSA 1926.
    • Incorporates force minimisation technology.
    • Corrosion resistant.
    • No access to roof underside required.
    • Designed for use with Kingspan roof panels and PV.
    • Compatible with most Kingspan insulated roof panels.
    • Can be installed during or after construction.
    • Available with the Kingspan Guarantee.

Technical Information

Compatibility with Kingspan Insulated Roof Panels

Trapezoidal Lo-Pitch Curved Roof K-Dek Topdek KingZip Roofliner
Safepro2

Design & Specification – Personal Protection Levels

 

 

PPE Level Summary Description Application Example
1 Restraint without requirement for PPE adjustment. Workers are restrained from reaching all fall hazards by attaching themselves to the fall protection system with PPE that requires no manual adjustment.

The system, as installed, should be proven capable of arresting falls.

System is fixed 2.5m back from the edge of a low pitch roof.
 

Worker is using a 2m long lanyard.
 

Within 5m of the roof edge, the worker is restrained from reaching the edge without the need to adjust PPE.
 

For roof locations over 5m from the edge, there is negligible risk of a fall. There is no need for PPE attachment.

2 Restraint with requirement for PPE adjustment. Workers are restrained from reaching all fall hazards by attaching themselves to the fall protection system with PPE that requires correct manual adjustment.

The system, as installed, should be proven capable of arresting falls.

System is fixed centrally on a roof.

Worker uses a rope with a grab.

For protection when accessing different areas of the roof, workers should manually adjust the length of their connection to the system.

Incorrect adjustment may result in a fall.

3 Fall arrest. Workers are not restrained from reaching fall hazards, but any fall occurance will be arrested in a controlled manner.

Fall clearance must be taken into consideration, and a rescue plan must be implemented before work begins.

A narrow roof area where it is not possible to prevent workers from reaching the edge, even when they are connected to a fall protection system.

Guarantee

In a single unique package, we cover the performance of your insulated panels and ancillary products in the following areas:
 

  • Coating performance – up to 15 years
  • Fire performance – up to 15 years
  • Thermal performance – up to 15 years
  • Structural performance – up to 15 years
  • Acoustic performance – up to 15 years

 