Kingspan Safepro2 Anchor & Cable System

A high-strength anchor and cable system with energy-absorbing posts that limit the fall arrest load to less than 6kN.
PBI_Logo_Asset_45_x_75_px-1

Specs & Details

  • Key features
  • Technical Information
UNRIVALLED FLEXIBILITY & APPLICATIONS

Kingspan's Safepro2 Cable System has been designed for use across all types of Kingspan Insulated Roof Panels; 

  • Trapezoidal
  • Lo-Pitch
  • Curved Roof
  • K-Dk
  • Topdek
  • KingZip
  • Roofliner
Key Features
  • Incorporates force minimisation technology.
  • Corrosion resistant.
  • No access to roof underside required.
  • Designed for use with Kingspan roof panels and PV.
  • Compatible with most Kingspan insulated roof panels.
  • Can be installed during or after construction.
  • Available with the Kingspan Guarantee.

A GUARANTEE YOU CAN COUNT ON

In a single unique package, we cover the performance of your insulated panels and ancillary products in the following areas:

  1. Coating performance – up to 15 years
  2. Fire performance – up to 15 years
  3. Thermal performance – up to 15 years
  4. Structural performance – up to 15 years
  5. Acoustic performance – up to 15 years

 

DESIGN, SPECIFICATION & INSTALLATION FLEXIBILITY

Whatever your roof profile build up, Kingspan Safepro2 is a great option. With a range of installation techniques possible, Safepro2 fits a range of requirements and personal protective levels. The table below highlights what personal protection is recommended as each level of installation. 

 

PPE Level Summary Description Application Example
1 Restraint without requirement for PPE adjustment. Workers are restrained from reaching all fall hazards by attaching themselves to the fall protection system with PPE that requires no manual adjustment.

 

The system, as installed, should be proven capable of arresting falls.

System is fixed 2.5m back from the edge of a low pitch roof.
 

 

Worker is using a 2m long lanyard.
 

Within 5m of the roof edge, the worker is restrained from reaching the edge without the need to adjust PPE.
 

For roof locations over 5m from the edge, there is negligible risk of a fall. There is no need for PPE attachment.

2 Restraint with requirement for PPE adjustment. Workers are restrained from reaching all fall hazards by attaching themselves to the fall protection system with PPE that requires correct manual adjustment.

 

The system, as installed, should be proven capable of arresting falls.

System is fixed centrally on a roof.

 

Worker uses a rope with a grab.

For protection when accessing different areas of the roof, workers should manually adjust the length of their connection to the system.

Incorrect adjustment may result in a fall.

3 Fall arrest. Workers are not restrained from reaching fall hazards, but any fall occurrence will be arrested in a controlled manner.

 

Fall clearance must be taken into consideration, and a rescue plan must be implemented before work begins.

A narrow roof area where it is not possible to prevent workers from reaching the edge, even when they are connected to a fall protection system.

 

STANDARDS
  • Fully compliant with AS NZS 1891.2 & 1891.4, BS EN 795: D and OHSA 1926.

 

Let's talk height safety!

Our products are manufactured in ISO-9001 accredited factories. All systems are marked CE complaint and confirm to all relevant AS/NZS and EN standards.

Resources

  • Video (1)
  • Documents (2)
idea

Have a project or question?

LET'S CHAT HEIGHT SAFETY - IT IS WHAT WE DO!

Lets Chat

Whether you’re after detailed drawings and a design specification or have a general questions about fall protection and working at height, we would love to hear from you.

For over 21 years our trusted team have been helping keep people and property safe at height. Afterall, making safety an instinctive culture is our vision. 

Looking to upload project details and engage with PBI Height Safety? Tell us about your project and upload drawings here. 

1